Showing results: 241 - 255 of 307 items found.
-
LSP-5KVA -
Lisun Electronics Inc.
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
Series JQE -
Kepco, Inc.
Series JQE power supplies are systems-type voltage stabilizers with current limiting. They are available in a variety of ratings: 100 watts in a 1/4-rack package, 250-500 watts in a 1/2-rack package, and 1000 watts in a full-rack package. These power supplies offer ultra low noise and ultra low ripple at the output. They are MIL-STD-461 compliant.The traditional analog meters (M Models) have been replaced by digital meters on DM models. Availability of models with analog meters is limited and they will be discontinued in the future.
-
Type NDB-2 and NDB-3 -
National RF, Inc
National RF’s Type NDB-2 and NDB-3 RF Milliwatt Meters are affordable pieces of test equipment for both the RF laboratory and the home experimenter. Both provide a digital reading of RF power in dB reference 1 milliwatt of power into a 50 ohm load (i.e. 0 dBm). The circuitry consists of a low noise logarithmic amplifier that drives a digital A/D converting meter circuit. The lowest power levels that can be read are about –73 dBm (approximately 40 microvolts or .00000003 milliwatts). The maximum power input should not exceed 10 milliwatts (+10 dBm or .010 watts) when inputed without attenuation. An internal attenuator is provided and described in the next section.
-
PAT-815 -
Sonel S.A.
TECHNICAL SPECIFICATIONFILESPAT-815 digital meter is used to measure the parameters of electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power, automatic measurement of all RCD parameters.
-
PRODIGIT Electronics Co, Ltd.
Digital Power Meter is designed to measure the power line parameters of AC / DC and DC / DC power supply. It is suitable for AC / DC Adapter, Charger, Quick Charger, LED Driver and DC / DC Converter. It is also suitable for uninterruptible power supply UPS, Regulators AVR, Inverter, batteries, AC / DC power supply / components ... and other applications.
-
PAT-806 -
Sonel S.A.
PAT-806 digital meters are used to measure the parameters of portable electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power. Specifically the instrument is dedicated to measure the welding equipment.
-
GAO Tek Inc.
GAOTek provides affordable, safe and reliable transmission line testers, digital clamp meters and power meters for sale to the United States, Canada and Globally. A transmission line is a specialized cable designed to conduct alternative current of radio frequency. Transmission lines are used for connecting radio transmitters and receivers with their antenna to distribute signals.
-
CA6017 Series -
UC Instruments, Corp.
The CA6017 Can transmit with a wavelength-identification digital encrypted protocol, enabling the FHP2 power meter to automatically use the proper calibration wavelength. This feature reduces the need for communication between the two technicians and decreases the possibility of making mistakes
-
4013A(300V / 20A) -
PRODIGIT Electronics Co, Ltd.
4013A Digital Power Meter is designed to measure the power line parameters of AC / DC and DC / DC power supply. It is suitable for AC / DC Adapter, Charger, Quick Charger, LED Driver and DC / DC Converter. It is also suitable for uninterruptible power supply UPS, Regulators AVR, Inverter, batteries, AC / DC power supply / components ... and other applications.
-
4015A(500V / 20A) -
PRODIGIT Electronics Co, Ltd.
4015A Digital Power Meter is designed to measure the power line parameters of AC / DC and DC / DC power supply. It is suitable for AC / DC Adapter, Charger, Quick Charger, LED Driver and DC / DC Converter. It is also suitable for uninterruptible power supply UPS, Regulators AVR, Inverter, batteries, AC / DC power supply / components ... and other applications.
-
SINEAX Series -
GMC-I Messtechnik GmbH
Heavy-current power meters are programmable and may be used for the measurement of almost all quantities of an electrical power system. The application (system configuration) as well as the behaviour of the analog and digital outputs are software configurable. The measurand acquisition via programming or bus interface during normal operation is also supported.
-
N432A -
Keysight Technologies
Keysight N432A is the replacement for Keysight's legacy 432A analog thermistor power meter. The single-channel, average RF power meter operates with the Keysight 8478B and 478A thermistor mounts. The N432A-and-thermistor-mount pair is ideal for applications that require high measurement accuracy, particularly in metrology and calibration laboratory environments. The enhanced thermistor power meter comes with a digital color LCD display, and user-friendly front panel interface. Its built-in calibration factor table provides a more convenient and accurate method of storing calibration factors as compared to the old knob-turning approach of the 432A. The N432A is LXI compliant, and programmable via GPIB, USB and LAN.
-
Elmeasure India Pvt. Ltd
Directly replaces 2 energy meters Sensing dual source through 240V connection Dual row display switches based on the source Displays basic and most of the power parameters Optional digital output separately for EB or DG parameters
-
SCR ELEKTRONIKS
The product is designed to carry out Arc Ignition Test as per IS/IEC 60947-1 Clause 8.2.1.1.2 (material used for electrical products). The adjustable current source is 230V AC @ 33A. The load is adjusted to get 32.5A at 0.5 power factor. Included on control unit are Digital Voltmeter, Digital Ammeter, Digital Power Factor Meter and Micro Controller based programmable Sequence Timer with LCD display for display & setting. The arrangement is made to mount the test piece with electrodes as per the specification given in the standard.
-
Wuhan Sunma Technology Co., Ltd.
Radio & Vector Network Analyzer adopts the advanced digital and RF combination design technology, fundamental wave frequency mixing technology, digital IF processing technology, intelligent power management technology, etc. It comes with features of high precision, small size, light weight, battery power, can measure SWR, Return Loss, Cable Loss, Impedance, DTF, etc, is used to the field test of cable, feeder, and the reflection parameters test of RF components in science and teaching. SunmaFiber provide all kinds of CATV meters, such as Signal Level Meter, QAM Analyzer, Spectrum Analyzer, DVB/DVC/DVT Analyzer and other TV testers.